Cari seluruh stasiun

Kap Aliran Udara Laminar GMP, Sistem Aliran Udara Laminar Ruang Bersih Kelas 100
Kap Aliran Udara Laminar GMP, Sistem Aliran Udara Laminar Ruang Bersih Kelas 100

Kap Aliran Udara Laminar GMP, Sistem Aliran Udara Laminar Ruang Bersih Kelas 100

Sorotan: langit-langit aliran laminar, bilik pengambilan sampel bahan baku Nama Produk: Kap Aliran Udara Laminar Tekanan Negatif Tingkat Pemurnian: Kelas 100 Spesifikasi: Sesuaikan Jenis Aliran......
  • Nama MerekXuzou Jiesen
  • Nomor ModelJS-P8
  • Waktu Pengiriman5-12 hari (tergantung pada kuantitas Anda)
  • HargaUntuk ditentukan
  • MOQ3 meter persegi
  • SertifikasiISO
  • Tempat AsalXuzhou, Tiongkok

Unduh data produk

Klik pesan online untuk menanyakan detail produk
Kirimkan pesan kepada kami dan kami akan menghubungi Anda sesegera mungkin
Kirimkan pesan kepada kami dan kami akan menghubungi Anda sesegera mungkin
*
*

lokalitas

Amerika UtaraEropaAmerika SelatanTimur TengahAsia*

tujuan

industri kimia Produksi makanan Laboratorium Instrumen presisi Manufaktur Elektronik Eksperimen Biologi Bidang medis

Pengalaman cerdas terbaik

Tonton video produk yang satu ini untuk mengetahui detail lebih lanjut

Detail Produk

Highlight: laminar flow ceiling, raw material sampling booth
Product Name:
Negative Pressure Laminar Air Flow Hood
Purification Levels:
Class 100
Specification:
Customize
Flow Type::
Vertical Laminar Flow
Usage:
Use Alone Or In Combination
Packaging:
Kasus Kayu
Terms:
CIF/EXW/FOB

Negative pressure GMP laminar air flow hood for pharmaceutical factory

1. GMP Laminar air flow hood description

According to the GMP (1998 revision) requirements, the current general pharmaceutical manufacturing plant is divided into 300,000, 100,000, 10,000, and 100, depending on the type of production. A clean grade, the 100th grade is the highest cleanliness level.

In a dust-free workshop of a pharmaceutical production plant, there will often be local 100-level areas, or require a certain room or several rooms to be class 100, or require certain areas in a room to be class 100. These 100 class areas are generally not large. , ranging from tens of square meters to a few square meters and even a fraction of square meters, is usually part of a process assembly line within a clean room. The Class 100 area is generally located in the inner area of the workshop, surrounded by 10,000 class or 100,000 class areas. The Class 100 area is part of the assembly line of the workshop. The entire assembly line also includes Class 10,000 or class 100,000. The 100-level area is generally lower in floor height (≤2.8m) and the environment is closed. It requires high noise and requires ≤65dB.

2.GMP Laminar air flow hood advantages

1). Purpose: The clean laminar flow hood is an air purification unit that can provide a local high clean environment and can be flexibly installed above the process requiring high cleanliness. Clean laminar flow hoods can be used individually or as multiple strips of clean areas. The device is a unidirectional flow purification device with top, side or bottom air inlet and bottom air supply, which can be widely used in electronics, pharmaceuticals, precision instruments, scientific research and other fields.

 

2). Principle: The clean laminar flow hood blows the pre-filtered air into the static pressure box with a certain wind speed, and then the hepa filter equalizes the pressure of the damping layer, so that the clean air flows vertically into the working area. , thus ensuring the cleanliness of the work area to achieve the process requirements.

 

3). Structure: There are three kinds of clean laminar flow hood with fan installed, fan installed above and fan installed. Mounting methods are suspended, floor stand and mobile. The structure can be divided into wall plate type, full iron shell paint, stainless steel outer shell iron and stainless steel and other forms.

 

3. Laminar air flow ceiling Parameter

 Model/parameter Class Ⅰ Class Ⅱ Class Ⅲ
Efficiency 99.99%
The wind speed(m/s) 0.45 0.3 0.23
Air supply size (mm) 2600×2400 2600×1800 2600×1400
Boundary dimension (mm) 2680×2480×500 2680×1880×500 2680×1480×500
Hepa size and QTY 610*305*292mm 8pcs 610*305*292mm 6pcs 610*305*292mm 4pcs
Usage occasion Class Ⅰ Special clean operating room. Class ⅡStandard clean operating room. Class Ⅲ General clean operating room.

 

Xuzhou Jiesen Environmental Protection Technology Co, Ltd mengkhususkan diri dalam menyediakan solusi dan produk pemurnian udara berkualitas tinggi untuk berbagai industri.

Perusahaan ini didedikasikan untuk produksi dan pengoperasian berbagai produk dan peralatan pemurnian udara industri, termasuk produk seperti filter udara primer, menengah, dan efisiensi tinggi, filter kimia, unit filter kipas FFU, saluran keluar udara efisiensi tinggi, kamar mandi udara, jendela pass-through, meja kerja yang bersih, dan produk pembersih dan pemurnian pendukung lainnya.

Produk-produk ini banyak digunakan dalam industri dan bidang seperti elektronik, semikonduktor, biofarmasi, pengolahan makanan, industri nuklir, manufaktur otomotif, AC dan HVAC, serta tempat umum.

Anda mungkin juga tertarik dengan produk ini

Situs web ini menggunakan cookie untuk meningkatkan pengalaman menjelajah Anda. Dengan terus menggunakan situs ini, Anda menerima penggunaan cookie kami. Data yang dikumpulkan dari situs web ini diproses dan disimpan di Amerika Serikat.

Mengerti!
1
Hubungi kami