モジュール式クリーンルーム設計
712 Viewsクリーンルーム・プロジェクトの予算価格について、ニーズについての情報があまりないまま、私たちに相談に来られることがよくあります。クリーンルームは投資であり、企業の戦略とニーズにおける真の資産です。
詳細を見る駅全体を検索
1、 There is no unified standard for air cleanliness in cleanrooms internationally, and each country has its own level standards. The provisions of China’s “Good Manufacturing Practice for Drugs” are as follows:
Cleanliness level Dust particle count/m3 Active microbial count
0.5 μ m 5 μ m planktonic bacteria/m3 sedimenting bacteria/dish
Level 100 ≤ 3500 0 ≤ 5 ≤ 1
10000 level ≤ 350000 ≤ 2000 ≤ 100 ≤ 3
100000 level ≤ 3500000 ≤ 20000 ≤ 500 ≤ 10
300000 level ≤ 10500000 ≤ 60000, currently missing ≤ 15
The clean room should maintain positive pressure, that is, the static pressure value of the high-level clean room should be higher than that of the low-level clean room; Cleanrooms are connected in order of cleanliness and have corresponding pressure differences (pressure difference ≥ 10mmH2O) to prevent air from low-level cleanrooms from flowing back to high-level cleanrooms; Unless there are special requirements for temperature and humidity in the process, the temperature in the clean room should be 18-26 ℃ and the relative humidity should be 45-65%.
2、 The commonly used methods for measuring dust concentration in clean rooms include light scattering method, membrane microscopy method, photoelectric colorimetric method, etc.
The light scattering method utilizes the principle that the intensity of the scattering method is proportional to the surface area of the dust particles, and the number of pulse signals corresponds to the number of dust particles. The particle size and number are displayed on a digital tube.
The membrane microscopy method uses microporous membrane vacuum filtration to filter dusty air, capturing dust particles on the surface of the membrane. Then, acetone vapor fumigation is used to form a transparent body on the membrane. After counting with a microscope, the physical properties such as shape, size, and color of the dust particles can be directly observed.
The photoelectric colorimetric method utilizes the principle that the optical density is proportional to the dust accumulation, and uses a photoelectric colorimeter to measure the difference in transmittance of the filter paper before and after filtration, directly measuring the dust content in the air.
In addition to using an air purifier to purify the air, a better method of purifying the air is ventilation.
クリーンルーム・プロジェクトの予算価格について、ニーズについての情報があまりないまま、私たちに相談に来られることがよくあります。クリーンルームは投資であり、企業の戦略とニーズにおける真の資産です。
詳細を見るクライアントはしばしば、"ISO 7クリーンルーム "や "ISO 8クリーンルーム "を特別に要求してくる。彼らがしばしば気づかないのは、ISOクラスはクリーンルームのレイアウトを定義するものではないということです。それは......
詳細を見るクリーンルーム市場は、規制の強化や安全性への関心の高まりにより、過去50年間で驚異的な成長を遂げてきた。さらに、現在ではコン・モジュール方式よりもモジュラー方式を選択する企業が増えている。
詳細を見るHVACシステムはクリーンルームの心臓部である。この話題を切り出すと、多くの顧客は気乗りしないが、HVACシステムはその中心的な役割を考えると、見過ごすことはできない。HVACは、クリーン・ルームの中核をなすシステムである。