모듈형 클린룸 설계
742 Views사람들은 종종 자신의 요구 사항에 대한 많은 정보 없이 클린룸 프로젝트에 대한 예산 가격을 문의합니다. 클린룸은 회사의 전략과 요구사항에 대한 투자이자 진정한 자산입니다......
세부 정보 보기전체 방송국 검색
Typically used in manufacturing or scientific research, a cleanroom is a controlled environment that has a low level of pollutants such as dust, airborne microbes, aerosol particles, and chemical vapors. To be exact, a cleanroom has a controlled level of contamination that is specified by the number of particles per cubic meter at a specified particle size. The ambient air outside in a typical city environment contains 35,000,000 particles per cubic meter, 0.5 micron and larger in diameter, corresponding to an ISO 9 cleanroom which is at the lowest level of cleanroom standards.
Cleanrooms are used in practically every industry where small particles can adversely affect the manufacturing process. They vary in size and complexity, and are used extensively in industries such as semiconductor manufacturing, pharmaceuticals, biotech, medical device and life sciences, as well as critical process manufacturing common in aerospace, optics, military and Department of Energy.
A cleanroom is any given contained space where provisions are made to reduce particulate contamination and control other environmental parameters such as temperature, humidity and pressure. The key component is the High Efficiency Particulate Air (HEPA) filter that is used to trap particles that are 0.3 micron and larger in size. All of the air delivered to a cleanroom passes through HEPA filters, and in some cases where stringent cleanliness performance is necessary, Ultra Low Particulate Air (ULPA) filters are used.
Personnel selected to work in cleanrooms undergo extensive training in contamination control theory. They enter and exit the cleanroom through airlocks, air showers and/or gowning rooms, and they must wear special clothing designed to trap contaminants that are naturally generated by skin and the body.
Depending on the room classification or function, personnel gowning may be as limited as lab coats and hairnets, or as extensive as fully enveloped in multiple layered bunny suits with self contained breathing apparatus.
Cleanroom clothing is used to prevent substances from being released off the wearer’s body and contaminating the environment. The cleanroom clothing itself must not release particles or fibers to prevent contamination of the environment by personnel. This type of personnel contamination can degrade product performance in the semiconductor and pharmaceutical industries and it can cause cross-infection between medical staff and patients in the healthcare industry for example.
Cleanroom garments include boots, shoes, aprons, beard covers, bouffant caps, coveralls, face masks, frocks/lab coats, gowns, glove and finger cots, hairnets, hoods, sleeves and shoe covers. The type of cleanroom garments used should reflect the cleanroom and product specifications. Low-level cleanrooms may only require special shoes having completely smooth soles that do not track in dust or dirt. However, shoe bottoms must not create slipping hazards since safety always takes precedence. A cleanroom suit is usually required for entering a cleanroom. Class 10,000 cleanrooms may use simple smocks, head covers, and booties. For Class 10 cleanrooms, careful gown wearing procedures with a zipped cover all, boots, gloves and complete respirator enclosure are required.
Cleanrooms maintain particulate-free air through the use of either HEPA or ULPA filters employing laminar or turbulent air flow principles. Laminar, or unidirectional, air flow systems direct filtered air downward in a constant stream. Laminar air flow systems are typically employed across 100% of the ceiling to maintain constant, unidirectional flow. Laminar flow criteria is generally stated in portable work stations (LF hoods), and is mandated in ISO-1 through ISO-4 classified cleanrooms.
Proper cleanroom design encompasses the entire air distribution system, including provisions for adequate, downstream air returns. In vertical flow rooms, this means the use of low wall air returns around the perimeter of the zone. In horizontal flow applications, it requires the use of air returns at the downstream boundary of the process. The use of ceiling mounted air returns is contradictory to proper cleanroom system design.
Cleanrooms are classified by how clean the air is. In Federal Standard 209 (A to D) of the USA, the number of particles equal to and greater than 0.5µm is measured in one cubic foot of air, and this count is used to classify the cleanroom. This metric nomenclature is also accepted in the most recent 209E version of the Standard. Federal Standard 209E is used domestically. The newer standard is TC 209 from the International Standards Organization. Both standards classify a cleanroom by the number of particles found in the laboratory’s air. The cleanroom classification standards FS 209E and ISO 14644-1 require specific particle count measurements and calculations to classify the cleanliness level of a cleanroom or clean area. In the UK, British Standard 5295 is used to classify cleanrooms. This standard is about to be superseded by BS EN ISO 14644-1.
Cleanrooms are classified according to the number and size of particles permitted per volume of air. Large numbers like “class 100” or “class 1000” refer to FED_STD-209E, and denote the number of particles of size 0.5 µm or larger permitted per cubic foot of air. The standard also allows interpolation, so it is possible to describe e.g. “class 2000.”
Small numbers refer to ISO 14644-1 standards, which specify the decimal logarithm of the number of particles 0.1 µm or larger permitted per cubic metre of air. So, for example, an ISO class 5 cleanroom has at most 105 = 100,000 particles per m³.
Both FS 209E and ISO 14644-1 assume log-log relationships between particle size and particle concentration. For that reason, there is no such thing as zero particle concentration. Ordinary room air is approximately class 1,000,000 or ISO 9.
Class | maximum particles/m3 | FED STD 209E equivalent |
|||||
>=0.1 µm | >=0.2 µm | >=0.3 µm | >=0.5 µm | >=1 µm | >=5 µm | ||
ISO 1 | 10 | 2 | |||||
ISO 2 | 100 | 24 | 10 | 4 | |||
ISO 3 | 1,000 | 237 | 102 | 35 | 8 | Class 1 | |
ISO 4 | 10,000 | 2,370 | 1,020 | 352 | 83 | Class 10 | |
ISO 5 | 100,000 | 23,700 | 10,200 | 3,520 | 832 | 29 | 클래스 100 |
ISO 6 | 1,000,000 | 237,000 | 102,000 | 35,200 | 8,320 | 293 | Class 1,000 |
ISO 7 | 352,000 | 83,200 | 2,930 | Class 10,000 | |||
ISO 8 | 3,520,000 | 832,000 | 29,300 | Class 100,000 | |||
ISO 9 | 35,200,000 | 8,320,000 | 293,000 | Room Air |
maximum particles/m3 | |||||
Class | >=0.5 µm | >=1 µm | >=5 µm | >=10 µm | >=25 µm |
Class 1 | 3,000 | 0 | 0 | 0 | |
Class 2 | 300,000 | 2,000 | 30 | ||
Class 3 | 1,000,000 | 20,000 | 4,000 | 300 | |
Class 4 | 20,000 | 40,000 | 4,000 |
쉬저우 지에센 환경 보호 기술 유한 회사는 다양한 산업에 고품질 공기 정화 솔루션과 제품을 제공하는 전문 기업입니다.
The company is dedicated to the production and operation of various industrial air purification products and equipment, including products such as primary, medium, and high-efficiency air filters, chemical filters, FFU fan filter units, high-efficiency air outlets, air shower rooms, pass-through windows, clean workbenches, and other 클린룸 and supporting purification products.
이러한 제품은 전자, 반도체, 바이오 제약, 식품 가공, 원자력 산업, 자동차 제조, 냉난방 및 공조, 공공장소 등의 산업 및 분야에서 널리 사용됩니다.
사람들은 종종 자신의 요구 사항에 대한 많은 정보 없이 클린룸 프로젝트에 대한 예산 가격을 문의합니다. 클린룸은 회사의 전략과 요구사항에 대한 투자이자 진정한 자산입니다......
세부 정보 보기고객들은 종종 "ISO 7 클린룸" 또는 "ISO 8 클린룸"을 구체적으로 요청하러 오곤 합니다. 그들이 종종 깨닫지 못하는 것은 ISO 등급이 클린룸의 레이아웃을 정의하지 않는다는 것입니다. ......
세부 정보 보기클린룸 시장은 지난 50년 동안 규제 강화와 안전에 대한 우려의 증가로 인해 엄청나게 성장했습니다. 또한, 이제 점점 더 많은 기업이 con......
세부 정보 보기HVAC 시스템은 클린룸의 핵심입니다. 많은 고객이 이 주제를 다룰 때 열성적이지 않지만, HVAC 시스템의 핵심적인 역할을 고려할 때 간과해서는 안 됩니다. HVAC는 행동입니다......
세부 정보 보기이 웹사이트는 사용자의 브라우징 경험을 개선하기 위해 쿠키를 사용합니다. 이 사이트를 계속 이용하면 쿠키 사용에 동의하는 것으로 간주됩니다. 이 웹사이트에서 수집된 데이터는 미국에서 처리 및 저장됩니다.
안녕하세요메시지를 남겨주세요.