Doorzoek het hele station
FFU:
|
1175*575*300mm Multiple
|
Materiaal:
|
SS304 Frame Or Aluminum Square
|
Zuiveringsniveaus:
|
Klasse 100-100000
|
Specificatie:
|
Aangepast
|
Muur::
|
Acrylic Sheet Or Toughened Glass
|
Verpakking:
|
Houten kist
|
Voorwaarden:
|
CIF/EXW/FOB
|
Levertijd:
|
7-15 dagen
|
Toepassing:
|
Pharmaceutical / Microelectron / Photoelectric / Food Productiion
|
Installation:
|
On-site Installation Or Installation Manual Online Instruction
|
Modular Clean Room Descripition:
With FFU(fan filter unit)as the core,clean booth provides a high level cleanliness.which draws in contaminated air from the top of the module,and exhausts filter clean air vertically in a unidicetional(Laminar) air stream at its base.is a self-contained fan and filter module for clean room applications.
It is a good option to create a cleaner space within an existing normal room or a room with low-level of cleanliness.
Als je het volgende doet, denk ik dat je de levensduur van de schone schuur effectief kunt verlengen..
1, temperatuur en vochtigheid. De temperatuur en vochtigheid van de clean booth worden meestal geregeld bij een verandering in de controlewaarde of in een bereik van 10%.
2, energiebesparing. Geproduceerd in een schone cabine verbruikt het apparaat veel energie, wat voornamelijk wordt veroorzaakt door het grote energieverbruik van het airconditioningsysteem. In het airconditioningsysteem van de schone cabine volgen het hoogrendementsfilter, het middelrendementsfilter en het effectfilter de langere bedrijfstijd en neemt de hoeveelheid stof die op het filter wordt geadsorbeerd geleidelijk toe, waardoor het drukverlies toeneemt en het luchtvolume afneemt. Daarom moet het primaire filter regelmatig worden vervangen en gereinigd.
3, behandeling en onderricht van binnenkomers. Aangezien stof de eerste factor is die de netheid kan beïnvloeden, moeten de werknemers die de schone loods binnengaan gezond zijn wat betreft hun mentale toestand en fysieke conditie, en moeten ze instructies krijgen om hun netheid te verbeteren. Verantwoordelijkheid voor het werken in de schuur. Wat nog belangrijker is, is om het inhoudelijke begrip van de reine stal zelf te verdiepen.
4, het omgaan met schone kleding. Zoals eerder vermeld, moet je schone werkkleding dragen als je een schone loods binnengaat. Vanuit het oogpunt dat er niet gestoft hoeft te worden, zijn de meeste kledingstukken volledige reinigingskleding van polyestervezels. Met de verlenging van het gebruik van de tijd zal de stofemissie van zo'n volledig schoon pak echter toenemen, dus moet er regelmatig worden schoongemaakt.
Our regular size of clean room Parameter
Parameter | Softwall Clean Booth(PVC) | Hardwall Clean Booth(Toughened glass,color steel panel) | ||
Cleanliness | From Class 100 to Class 100,000 | |||
External Dimension | As per requirement | |||
FFU | Dimension | 2*2/2*4/4*4 | ||
Cabinet Material | Roestvrij staal | |||
Power source | 110V/60hz/av/dc, 220V/60HZ/AV/DC | |||
HEPA Filter | H14 Hepa filter | |||
Frame Material | Roestvrij staal | |||
Wall Material | Anti-static soft PVC wall 106~109Ω | Anti-static acrylic 106~109Ω | ||
Lighting | Lamps | Available in LED and T5 | ||
Air condition | As per requirement | Available in constant temperature air conditioner/constant temperature and humidity conditioner | ||
Class Level | Model | Inner dimension | Number of | Air volume(m3/h) |
W * D * H (mm) | FFU | |||
Class100 | ALCS6 * 8 | 2000 * 3000 * 2200 | 6 | 6600 |
ALCS 8 * 12 | 2440 * 3660 * 2200 | 12 | 13200 | |
ALCS 8 * 16 | 2450 * 4880 * 2200 | 16 | 17600 | |
ALCS 8 * 20 | 2440 * 6100 * 2200 | 20 | 22000 | |
Class 1000 | ALCS6 * 8 | 2000 * 3000 * 2200 | 2 | 2200 |
ALCS 8 * 16 | 2440 * 4880 * 2200 | 4 | 4400 | |
ALCS 12 * 16 | 3660 * 4880 * 2200 | 6 | 6600 | |
ALCS 20 * 24 | 6100 * 7300 * 2200 | 12 | 13200 | |
Class 10000 | ALCS6 * 8 | 2000 * 3000 * 2200 | 1 | 1100 |
ALCS 8 * 16 | 2440 * 4880 * 2200 | 2 | 2200 | |
ALCS 12 * 16 | 3660 * 4880 * 2200 | 4 | 4400 | |
ALCS 20 * 24 | 6100 * 7300 * 2200 | 8 | 8800 |
Hardwall modular cleanroom offer a completely enclosed, rigid cleanroom option with vents to exhaust air. Hardwall cleanrooms can maintain pressure differentials, which may be required to meet certain standards for cleanliness.
Highlight: cleanroomcabine oem, cleanroomcabine klasse 100, cleanroomcabine klasse 100 Temperatur......
Highlight: industriële schone ruimte cabine, contaminatie controle schone ruimte cabine, lucht distribu......
Markeer: ISO6 Zacht Gordijn, Antistatisch Zacht Gordijn, Clean Room Zacht Gordijn Productnaam: ......
De (SS-MAC) is een betaalbare en aanpasbare cleanroomunit. Het is verpakt als een DIY (doe-het-zelf......
De Laminar Flow Clean Booth biedt een steriele werkomgeving. De laminaire stroming is continu ......
Schone cabines worden gebruikt voor plaatselijke of geavanceerde reiniging van deeltjes om cleanroom-standaarden te bereiken......
Product Introductie Een cleanroom is een eenvoudig zuiveringsapparaat met een lage investering, een hoge zuiverheid......
Een hardwandige cleanroom voor de productie van medische apparatuur vereist precisie op elk kruispunt, ......
Deze website gebruikt cookies om uw surfervaring te verbeteren. Door deze website te blijven gebruiken, accepteert u het gebruik van onze cookies. Gegevens die via deze website worden verzameld, worden verwerkt en opgeslagen in de Verenigde Staten.