Pesquisar toda a estação

Modular Clean Room Design Acrylic Sheet Hard Wall Portable Clean Room
Modular Clean Room Design Acrylic Sheet Hard Wall Portable Clean Room

Modular Clean Room Design Acrylic Sheet Hard Wall Portable Clean Room

Highlight: Acrylic Sheet Portable Clean Room, SS304 frame Portable Clean Room, Acrylic Sheet Modular Clean Room FFU: 1175*575*300mm Multiple Material: SS304 Frame Or Aluminum Square Pu……
  • Nome da marcaXuzou Jiesen
  • Número do modeloJS-P8
  • Prazo de entrega5-12 dias (depende da quantidade)
  • PreçoA determinar
  • MOQ3 metros quadrados
  • CertificaçãoISO
  • Local de origemXuzhou,China

Descarregamento de dados do produto

Clique na mensagem online para obter informações sobre os detalhes do produto
Envie-nos uma mensagem e entraremos em contacto consigo o mais rapidamente possível
Envie-nos uma mensagem e entraremos em contacto consigo o mais rapidamente possível
*
*

localidade

América do NorteEuropaAmérica do SulMédio OrienteÁsia*

objetivo

indústria química Produção alimentar Laboratório Instrumentos de precisão Fabrico eletrónico Experiência biológica Domínio médico

A derradeira experiência inteligente

Veja o vídeo deste produto para saber mais pormenores

Detalhes do produto

Highlight: Acrylic Sheet Portable Clean Room, SS304 frame Portable Clean Room, Acrylic Sheet Modular Clean Room
FFU:
1175*575*300mm Múltiplo
Material:
Estrutura SS304 ou quadrado de alumínio
Níveis de purificação:
Class 100-100000
Especificação:
Personalizado
Wall::
Folha de acrílico ou vidro temperado
Embalagem:
Caixa de madeira
Condições:
CIF/EXW/FOB
Delivery Time:
7-15days
Aplicação:
Farmacêutico / Microelectrão / Fotoelétrico / Produção alimentar
Instalação:
Instalação no local ou manual de instalação Instruções online

Folha de acrílico profissional Parede dura Sala limpa portátil Design modular de sala limpa

 

Modular Clean Room Descripition:

 

Com a FFU (unidade de filtro de ventilador) como núcleo, a cabine limpa fornece um alto nível de limpeza. Ela aspira o ar contaminado da parte superior do módulo e exaure o ar limpo do filtro verticalmente em um fluxo de ar unidirecional (laminar) em sua base.

É uma boa opção para criar um espaço mais limpo numa divisão normal existente ou numa divisão com baixo nível de limpeza.

If you do the following, I believe that you can effectively extend the life of the clean room.

1, temperature and humidity. The temperature and humidity of the clean booth are usually controlled in the case of a change in the control value or in a range of 10%.
2, energy saving. Produced in a clean shed, the unit consumes a lot of energy, which is mainly caused by the large power consumption of the air-conditioning system. In the air-conditioning system of the clean booth, the high-efficiency filter, medium-efficiency filter, and effect filter follow the prolonged operation time, and the amount of dust adsorbed on the filter gradually increases, causing the pressure loss to increase and the air volume to decrease. Therefore, the primary filter must be replaced and cleaned frequently.
3, entrants handling and teaching. Since the first factor that may affect cleanliness is dust, the workers entering the clean shed must be healthy in their mental state and physical condition, and they must be instructed to improve their cleanliness. Responsibility for working in the shed. What is more important is to deepen the substantive understanding of the clean shed itself.
4, the handling of clean clothes. As mentioned earlier, clean work clothes must be worn when entering a clean shed. From the perspective of no dusting, most of them are full-blown cleansing clothes made of polyester fibers. However, with the extension of the use of time, the dust emission of such a full-scale clean suit will increase, so regular cleaning must be performed.

 

 

O nosso tamanho normal de sala limpa Parâmetro

Parâmetro Cabina de limpeza Softwall (PVC) Cabina de limpeza com parede dura (vidro temperado, painel de aço colorido)
Limpeza Da classe 100 à classe 100.000
Dimensão externa Conforme a necessidade
FFU Dimensão 2*2/2*4/4*4
Material do armário Aço inoxidável
Fonte de alimentação 110V/60hz/av/dc, 220V/60HZ/AV/DC
Filtro HEPA H14 Filtro Hepa
Material da estrutura Aço inoxidável
Material da parede Parede de PVC macio anti-estático 106~109Ω Acrílico anti-estático 106~109Ω
Iluminação Candeeiros Disponível em LED e T5
Ar condicionado Conforme a necessidade Disponível em ar condicionado de temperatura constante/ar condicionado de temperatura e humidade constantes
Nível de classe Modelo Dimensão interior Número de Volume de ar (m3/h)
L * P * A (mm) FFU
Classe100 ALCS6 * 8 2000 * 3000 * 2200 6 6600
ALCS 8 * 12 2440 * 3660 * 2200 12 13200
ALCS 8 * 16 2450 * 4880 * 2200 16 17600
ALCS 8 * 20 2440 * 6100 * 2200 20 22000
Classe 1000 ALCS6 * 8 2000 * 3000 * 2200 2 2200
ALCS 8 * 16 2440 * 4880 * 2200 4 4400
ALCS 12 * 16 3660 * 4880 * 2200 6 6600
ALCS 20 * 24 6100 * 7300 * 2200 12 13200
Classe 10000 ALCS6 * 8 2000 * 3000 * 2200 1 1100
ALCS 8 * 16 2440 * 4880 * 2200 2 2200
ALCS 12 * 16 3660 * 4880 * 2200 4 4400
ALCS 20 * 24 6100 * 7300 * 2200 8 8800

As salas limpas modulares com paredes rígidas oferecem uma opção de sala limpa rígida e completamente fechada, com aberturas para a exaustão do ar. As salas limpas de parede dura podem manter diferenciais de pressão, que podem ser necessários para cumprir determinadas normas de limpeza.

A construção com paredes rígidas permite o controlo da temperatura e da humidade, bem como a contenção por pressão negativa para criar um fluxo laminar de ar sem partículas.

Também pode estar interessado nestes produtos

Este sítio Web utiliza cookies para melhorar a sua experiência de navegação. Ao continuar a utilizar este sítio, o utilizador aceita a utilização dos nossos cookies. Os dados recolhidos neste sítio Web são processados e armazenados nos Estados Unidos.

Já está!
1
Contactar-nos