搜索整个车站
产品名称
|
Negative Pressure Laminar Air Flow Hood
|
净化级别:
|
100 级
|
规格
|
Customize
|
Flow Type::
|
Vertical Laminar Flow
|
Usage:
|
Use Alone Or In Combination
|
包装
|
木箱
|
条款:
|
CIF/EXW/FOB
|
According to the GMP (1998 revision) requirements, the current general pharmaceutical manufacturing plant is divided into 300,000, 100,000, 10,000, and 100, depending on the type of production. A clean grade, the 100th grade is the highest cleanliness level.
In a dust-free workshop of a pharmaceutical production plant, there will often be local 100-level areas, or require a certain room or several rooms to be class 100, or require certain areas in a room to be class 100. These 100 class areas are generally not large. , ranging from tens of square meters to a few square meters and even a fraction of square meters, is usually part of a process assembly line within a clean room. The Class 100 area is generally located in the inner area of the workshop, surrounded by 10,000 class or 100,000 class areas. The Class 100 area is part of the assembly line of the workshop. The entire assembly line also includes Class 10,000 or class 100,000. The 100-level area is generally lower in floor height (≤2.8m) and the environment is closed. It requires high noise and requires ≤65dB.
1). Purpose: The clean laminar flow hood is an air purification unit that can provide a local high clean environment and can be flexibly installed above the process requiring high cleanliness. Clean laminar flow hoods can be used individually or as multiple strips of clean areas. The device is a unidirectional flow purification device with top, side or bottom air inlet and bottom air supply, which can be widely used in electronics, pharmaceuticals, precision instruments, scientific research and other fields.
2). Principle: The clean laminar flow hood blows the pre-filtered air into the static pressure box with a certain wind speed, and then the hepa filter equalizes the pressure of the damping layer, so that the clean air flows vertically into the working area. , thus ensuring the cleanliness of the work area to achieve the process requirements.
3). Structure: There are three kinds of clean laminar flow hood with fan installed, fan installed above and fan installed. Mounting methods are suspended, floor stand and mobile. The structure can be divided into wall plate type, full iron shell paint, stainless steel outer shell iron and stainless steel and other forms.
型号/参数 | Ⅰ类 | 第Ⅱ类 | 第Ⅲ类 |
效率 | 99.99% | ||
风速(米/秒) | 0.45 | 0.3 | 0.23 |
供气尺寸(毫米) | 2600×2400 | 2600×1800 | 2600×1400 |
边界尺寸(毫米) | 2680×2480×500 | 2680×1880×500 | 2680×1480×500 |
空气过滤器尺寸和数量 | 610*305*292 毫米 8 件 | 610*305*292 毫米 6 件 | 610*305*292 毫米 4 件 |
使用场合 | Ⅰ级特殊洁净手术室。 | Ⅱ级标准洁净手术室。 | Ⅲ级一般洁净手术室。 |
亮点: 100 级无尘室、无尘室岗亭 OEM、无尘室岗亭等级 100、无尘室岗亭等级 100 温度......
亮点:工业级无尘室、污染控制无尘室、空气分配......
亮点:ISO6 软门帘、防静电软门帘、无尘室软门帘 产品名称 ......
SS-MAC 是一种经济实惠、适应性强的无尘室设备。它采用 DIY(自己动手做......)包装。
层流洁净室提供无菌工作环境。层流净化槽可连续......
洁净室可用于局部或高级粒子清洁,以达到洁净室标准......。
产品介绍 无尘室是一种投资少、纯度高的简易净化装置......。
用于医疗设备制造的硬壁洁净室要求每个交叉点都要精确无误, ......
本网站使用 cookie 改善您的浏览体验。继续使用本网站即表示您接受使用我们的 cookie。本网站收集的数据在美国处理和存储。